Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Produktübersicht

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Wichtigste Merkmale

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Verfügbare Modelle / Konfigurationen

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceKonfigurationSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Technische Daten

Mounting threadM40 × 1.5 with nut
AbmessungenØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Anwendungen

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Schaltkästen für den Außenbereich

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Für die Auswahl zu bestätigende Informationen

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Häufig gestellte Fragen

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Angebot anfordern

Bitte teilen Sie uns das genaue Modell, die erforderlichen Nennleistungen, die Menge und den Bestimmungsort mit. Wir werden vor der Angebotserstellung die Verfügbarkeit und die erforderlichen Unterlagen prüfen.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Produktinformationen und Preise anfordern

Bitte teilen Sie uns die Modellnummern, Nennleistungen, Mengen und Angaben zum Bestimmungsort mit. Wir prüfen die Verfügbarkeit, bevor wir Ihnen ein Angebot unterbreiten.

Zum Seitenanfang scrollen