Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Descripción general del producto

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Características principales

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Modelos y configuraciones disponibles

Utilice estas referencias de configuración a modo de consulta; confirme las especificaciones exactas antes de realizar el pedido.

Referencia de configuración de RITOKSConfiguraciónNotas sobre la selección
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Especificaciones técnicas

Mounting threadM40 × 1.5 with nut
DimensionesØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Aplicaciones

Contexto conceptual de la aplicación generado por IA; no se trata de una fotografía de una instalación real. Comprueba que el equipo sea compatible y que se cumplan los requisitos de los circuitos para la configuración seleccionada.

Outdoor Control Cabinets — AI conceptual application illustration

Armarios de control para exteriores

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Datos que hay que confirmar para la selección

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Preguntas frecuentes

¿Qué datos se necesitan para elaborar un presupuesto?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

¿Qué hay que comprobar antes de elegir una configuración?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Solicitar un presupuesto

Indíquenos el modelo exacto, las potencias nominales requeridas, la cantidad y el destino. Le confirmaremos la disponibilidad y la documentación antes de enviarle el presupuesto.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.