Nu informeren
RTX-PCV40-S Cabinet Pressure Compensation Devices — representative product photograph

Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Productoverzicht

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Belangrijkste kenmerken

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Beschikbare modellen / configuraties

Raadpleeg deze configuratiegegevens ter informatie; controleer de exacte specificaties voordat u een bestelling plaatst.

RITOKS-configuratiegidsConfiguratieToelichting bij de selectie
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Technische specificaties

Mounting threadM40 × 1.5 with nut
AfmetingenØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Toepassingen

Door AI gegenereerde conceptuele toepassingscontext; dit is geen foto van een daadwerkelijke installatie. Controleer of de apparatuur geschikt is en of aan de stroomvereisten voor de geselecteerde configuratie wordt voldaan.

Outdoor Control Cabinets — AI conceptual application illustration

Buitenkastjes voor besturingssystemen

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Te controleren gegevens voor de selectie

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Veelgestelde vragen

Welke gegevens zijn nodig voor een offerte?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

Wat moet je controleren voordat je een configuratie kiest?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Vraag een offerte aan

Geef het exacte model, de vereiste vermogens, het aantal stuks en de bestemming door. Wij zullen de beschikbaarheid en de benodigde documentatie controleren voordat we een offerte opstellen.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Productinformatie en prijzen opvragen

Geef de modelnummers, specificaties, aantallen en gegevens over de bestemming door. Wij zullen de beschikbaarheid controleren voordat we een offerte opstellen.

Naar boven scrollen