Запитати зараз
RTX-PCV40-S Cabinet Pressure Compensation Devices — representative product photograph

Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Огляд продукту

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Основні особливості

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Доступні моделі / конфігурації

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceКонфігураціяSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Технічні характеристики

Mounting threadM40 × 1.5 with nut
РозміриØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Застосування

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Шафи управління для зовнішнього встановлення

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Інформація, яку необхідно підтвердити для відбору

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Часті запитання

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Замовити розрахунок вартості

Надішліть точну модель, необхідні технічні характеристики, кількість та місце призначення. Перед наданням комерційної пропозиції ми перевіримо наявність товару та необхідні документи.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Замовити інформацію про товар та ціни

Надішліть номери моделей, технічні характеристики, кількість та дані про місце призначення. Ми перевіримо наявність товару перед складанням комерційної пропозиції.

Прокрутити до початку сторінки