RTX-MGW4 Modbus RTU-to-TCP Gateways
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.
ModbusRTU → TCP
4RS485 interfaces
12–24 V DCTedarik
DIN rayıMontaj
Ürün Genel Bakışı
DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Temel Özellikler
- Protocol scope: Modbus RTU to Modbus TCP variant
- RS485 interfaces: 4
- RS232 interface: 1
- USB interface: 1 OTG
- Dry-contact I/O: 3 inputs / 3 outputs
Mevcut Modeller / Konfigürasyonlar
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Yapılandırma | Selection notes |
|---|---|---|
| RTX-MGW4-RT | RTU-to-TCP gateway | Verify supported device map and firmware |
Teknik Özellikler
| Protocol scope | Modbus RTU to Modbus TCP variant |
|---|---|
| RS485 interfaces | 4 |
| RS232 interface | 1 |
| USB interface | 1 OTG |
| Dry-contact I/O | 3 inputs / 3 outputs |
| Tedarik | 12–24 V DC |
| Boyutlar | 144 × 90 × 63.5 mm |
| Çalışma sıcaklığı | −20 to +60 °C |
Başvurular
AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms
Connect compatible RTU devices to a supervisory TCP network.
Energy Monitoring Networks
Integrate meters only after checking register maps and polling limits.
Endüstriyel Otomasyon
Review port assignments, network addressing and gateway configuration.
Seçim İçin Doğrulanması Gereken Bilgiler
- Device protocols, register maps and intended network topology
- Number of RTU devices and required polling rate
- Power supply and cabinet dimensions
- Firmware and commissioning requirements
Sık Sorulan Sorular
What information is needed for a quotation?
Device protocols, register maps and intended network topology Please include quantity and destination.
What should be confirmed before selecting a configuration?
Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.
Fiyat Teklifi İsteyin
Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.
Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.