RITOKS Modbus gateway with white DIN-rail housing and multiple terminal interfaces

Electrical Measurement & Monitoring · RTX-MGW4

RTX-MGW4 Modbus RTU-to-TCP Gateways

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version.

ModbusRTU → TCP

4RS485 interfaces

12–24 V DCПостачання

DIN-рейкаМонтаж

Огляд продукту

DIN-rail gateways connect supported Modbus RTU equipment to a Modbus TCP network. This candidate is scoped to the RTU-to-TCP variant, not the separately offered BACnet version. Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

Основні особливості

  • Protocol scope: Modbus RTU to Modbus TCP variant
  • RS485 interfaces: 4
  • RS232 interface: 1
  • USB interface: 1 OTG
  • Dry-contact I/O: 3 inputs / 3 outputs

Доступні моделі / конфігурації

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceКонфігураціяSelection notes
RTX-MGW4-RTRTU-to-TCP gatewayVerify supported device map and firmware

Технічні характеристики

Protocol scopeModbus RTU to Modbus TCP variant
RS485 interfaces4
RS232 interface1
USB interface1 OTG
Dry-contact I/O3 inputs / 3 outputs
Постачання12–24 V DC
Розміри144 × 90 × 63.5 mm
Робоча температура−20 to +60 °C

Застосування

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Building Plant Rooms — AI conceptual application illustration

Building Plant Rooms

Connect compatible RTU devices to a supervisory TCP network.

Energy Monitoring Networks

Integrate meters only after checking register maps and polling limits.

Промислова автоматизація

Review port assignments, network addressing and gateway configuration.

Інформація, яку необхідно підтвердити для відбору

  • Device protocols, register maps and intended network topology
  • Number of RTU devices and required polling rate
  • Power supply and cabinet dimensions
  • Firmware and commissioning requirements

Часті запитання

What information is needed for a quotation?

Device protocols, register maps and intended network topology Please include quantity and destination.

What should be confirmed before selecting a configuration?

Port counts do not establish throughput or device capacity. BACnet functionality is outside this RTU-to-TCP configuration.

Замовити розрахунок вартості

Надішліть точну модель, необхідні технічні характеристики, кількість та місце призначення. Перед наданням комерційної пропозиції ми перевіримо наявність товару та необхідні документи.

Please include: Device protocols, register maps and intended network topology; Number of RTU devices and required polling rate; Power supply and cabinet dimensions.