RTX-PCV40-S Cabinet Pressure Compensation Devices — representative product photograph

Enclosure Climate Controls · RTX-PCV40-S

RTX-PCV40-S Cabinet Pressure Compensation Devices

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation.

M40 × 1.5Mounting thread

Ø60 × 37 mmOverall dimensions

NBRGasket material

−35 to +70 °CListed temperature

Tổng quan về sản phẩm

Thread-mounted membrane devices provide pressure equalization for electrical enclosures. The M40 candidate uses a gasket and mounting nut; enclosure protection depends on the complete installation. Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Các tính năng chính

  • Mounting thread: M40 × 1.5 with nut
  • Dimensions: Ø60 × 37 mm
  • Mounting depth: Approximately 16 mm
  • Tightening torque: 5 Nm; published maximum 10 Nm
  • Seal: NBR gasket

Các mẫu / cấu hình có sẵn

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceCấu hìnhSelection notes
RTX-PCV40-SM40 × 1.5Confirm gasket, enclosure wall and installation

Thông số kỹ thuật

Mounting threadM40 × 1.5 with nut
Kích thướcØ60 × 37 mm
Mounting depthApproximately 16 mm
Tightening torque5 Nm; published maximum 10 Nm
SealNBR gasket
MembraneWaterproof membrane
Air permeability1200 l/h at pressure difference of at least 70 mbar
Temperature range−35 to +70 °C

Ứng dụng

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Outdoor Control Cabinets — AI conceptual application illustration

Tủ điều khiển ngoài trời

Evaluate pressure equalization under changing outdoor conditions.

Industrial Enclosures

Coordinate membrane devices with enclosure sealing and cable entries.

Cabinet Climate Design

Consider separately selected heaters, fans and humidity controls.

Thông tin cần xác nhận để tiến hành lựa chọn

  • Enclosure volume, pressure conditions and required protection documentation
  • Wall thickness, thread opening and installation clearance
  • Temperature and exposure conditions
  • Required quantity and gasket arrangement

Câu hỏi thường gặp

What information is needed for a quotation?

Enclosure volume, pressure conditions and required protection documentation Please include quantity and destination.

What should be confirmed before selecting a configuration?

Air permeability applies at the stated pressure difference, not unrestricted ventilation. A membrane vent is not a cooling fan.

Yêu cầu báo giá

Vui lòng cung cấp thông tin chính xác về mẫu sản phẩm, thông số kỹ thuật yêu cầu, số lượng và địa điểm nhận hàng. Chúng tôi sẽ xác nhận tình trạng hàng có sẵn và các thủ tục giấy tờ trước khi gửi báo giá.

Please include: Enclosure volume, pressure conditions and required protection documentation; Wall thickness, thread opening and installation clearance; Temperature and exposure conditions.

Yêu cầu thông tin sản phẩm và giá cả

Vui lòng gửi mã sản phẩm, thông số kỹ thuật, số lượng và thông tin về địa điểm giao hàng. Chúng tôi sẽ xác nhận tình trạng hàng có sẵn trước khi lập báo giá.

Cuộn lên đầu trang